FlexyTSC – Adaptable Thermal Screening Calorimeter system

products-servicesSYSTAG, System Technik AG
April 29th 2014

FlexyTSC is an adiabatic Thermal Screening Calorimeter that provides experts with support in safety analyses of solids and liquids as well as non-homogeneous substances.

FlexyTSC is specifically designed to provide all necessary data for safety inspection in the following areas:

  • Scale-up
  • Process safety
  • Thermal stability
  • Warehouse test
  • Risk analysis
  • Runaway scenarios

The system allows up to six measuring cells to be operated simultaneously, yet monitored individually. Samples in multi-gram range enable analyses of non-homogeneous substances that extend right through to distillation residue.

FlexyTSC eliminates need for specific sample preparation with consequent difficulties, guaranteeing reproducible objective analyses even under adiabatic conditions.

Functions

Thermodynamic evaluations with FlexyTSC offer clear analyses of undesired decomposition reactions or autocatalytic reactions with regard to:

Thermal Process Safety - FlexyTSC

  • Onset temperature
  • Heat of decomposition
  • SHR (self-heating rate)
  • Arrhenius plot
  • TMR plot (time to maximum rate)
  • Activation energy
  • Antoine plot

The system provides dynamic measurement for detecting onset and decomposition enthalpy with isothermal multi-step experiment to assess autocatalytic decomposition.

The long-term isothermal measurement can verify storage and transportation stability.

Adiabatic measurement capability can determine SADT data and be combined with the Heat-Wait-Search function to calculate TMR (time to maximum rate), self-heating rate and activation energy, to complete the full Runaway-Scenario.

Flexibility and adaptability

FlexyTSC supports measurements using open or closed glass vessels, or with gas-flow-meter and at various gas atmospheres. It is suitable for both solids and liquids.

It also supports analysis of solids or liquids in pressure vessels that can be fitted with glass inliner to suppress catalytic influences, with optional pressure measurement.

The system can be configured to measure data ranging from -50°C to 400°C, with sample volumes ranging from 0.5 cc up to approximately 500 cc and pressures up to 200 bar.

A wide selection of sample vessels enables comprehensive analyses meeting specific pressure, gas measurement, inert or active gas requirements. Sample vessels are reusable to reduce cost per analysis.

Resources

Click on adaptable Thermal Screening Calorimeter system – FlexyTSC, for other information.
Click on SYSTAG to contact the company directly.


Supplier Information
Supplier: SYSTAG, System Technik AG
Address: Bahnhofstrasse 76, CH-8803 Rüschlikon, Switzerland
Tel: +41 (0)44 704 54 54
Fax: +41 (0)44 704 54 55
Website: www.systag.ch


SYSTAG, System Technik AG

Contact Information
Address: Bahnhofstrasse 76, CH-8803 Rüschlikon, Switzerland
Telephone No: +41 (0)44 704 54 54
Email Address: infos@systag.ch
Web Address: http://www.systag.ch

Contact SYSTAG, System Technik AG

Simply fill out the form below to contact SYSTAG, System Technik AG now.

Send SYSTAG, System Technik AG a Message